alcon sa60at a constant


[253]: data by Prof.Dr.M.Bhnke, Hamburg, Germany [65]: data by Dr.M.V.Partyngl, Wil, Switzerland [69]: data by Dr.H.Strobl, Rosenheim, Germany [64]: data by Dr.U.Weimantel, Frth, Germany [398]: data by Dres. [377]: data by Prof. Dr. Thomas Olsen, Aarhus, Denmark Hoya iMics1 NY-60 (Japan) A=118.4 a0=1.29 a1=0.40 a2=0.10 pACD=5.46 sf=1.66 A=118.7 A=118.9 45 [41] [260]: data by D.Taglia MD, Munster, IN, USA [99]: data by IOLtech [24]: data by Dr.R.Kll, Landshut, Germany [390]: data by Dr. C. Kloos & Dr. B. Pleisch, Augenzentrum Wil, Switzerland Biotech Vision Eyecryl Plus HSAS600 A=118.0 a0=1.03 a1=0.40 a2=0.10 pACD=5.13 sf=1.37 A=118.3 A=118.5 58 [369] [308]: data by Dr.B.Mathys, Bruxelles, Belgium [288]: data by Aurolab, India Product number SA60AT IOLS AcrySof IQ IOL 6,0 AcrySof Multipiece 6,0 AcrySof Multipiece EXpand -1,0 AcrySof single piece 31,0 Capsular Tension Ring, ca 11mm Capsular Tension Ring, ca 12mm MA60AC MONARCH III (C) CARTRIDGES MODIFIED MONARCH III (D) CARTRIDGES SGL USE MONARCH III IOL DELIVERY SYSTHANDPIECE PMMA Single piece IOL 10,0 [336]: data by Dr. Jean Philippe Seguin, Nevers, France Ocular Implants, Lens Implants, and Devices More. [380]: data by Dr. LEE Junhun, Daegu, South Korea P.Hoffmann MD(Castrop-Rauxel, Germany), [127]: data by H.Geggle MD,Seattle, WA, USA Graefes Arch Clin Exp Ophthalmol. [268]: data by Dr. F.Kesteloot, Kortrijk, Belgium [275]: data by Dr.J.C.P.Lightvoet, Dokkum, The Netherlands [278]: data by Jason Jacobs, MD, Denver, CO, USA Domilens Nidek Nex-Acri N4-18YG AKTIS AA A=118.4 a0=1.34 a1=0.40 a2=0.10 pACD=5.51 sf=1.73 A=118.9 A=119.2 57 [257] [39]: data by Ronald R.Holweger, MD, Hays, KS, USA HumanOptics Torica-aA(Y) A=118.4 a0=1.18 a1=0.40 a2=0.10 pACD=5.35 sf=1.51 A=118.3 A=118.4 44 [397] We are here to respond to your inquiries like choosing the best patient platform, or data storage, or any other solution for your needs. [304]: data by Dr.H.Kaymak, Dr.D.Breyer, Dsseldorf, Germany ACRYSOF Aspheric UV Absorbing ReSTOR +2.5 D Toric IOL, ACRYSOF IQ RESTOR +2.5 D Multifocal Toric IOL, ACRYSOF IQ RESTOR +3.0 D Multifocal Toric IOL, ACRYSOF MultiPiece - Posterior Convex IOL & EXPAND Series IOLs, AIR OPTIX AQUA Multifocal Contact Lenses, AIR OPTIX for Astigmatism Contact Lenses, AIR OPTIX NIGHT & DAY AQUA Contact Lenses, AIR OPTIX plus HydraGlyde Contact Lenses, AIR OPTIX plus HydraGlyde for Astigmatism Contact Lenses, AIR OPTIX plus HydraGlyde Multifocal Contact Lenses, (proparacaine hydrochloride ophthalmic solution, USP) 0.5%, Anterior Chamber Lenses - KELMAN MULTIFLEX III PMMA Single-Piece IOL. [349]: data by Dr.Dhaval S. Modi, Ahmedabad, India [109]: data by Dr.W.Lange, Prien, Germany Brazil [264]: data by Dr. C.Niederdellmann, Friedberg, Germany We aspire to lead the world in innovating life-changing vision and eye care products because when people see brilliantly, they live brilliantly 2021 Corporate Responsibility Report Learn more Sight Innovation ZEISS Acri.Lens 12C A=118.9 a0=1.42 a1=0.40 a2=0.10 pACD=5.64 sf=1.91 A=119.2 A=119.5 16 [2] Staar AQ 2010 A=118.5 a0=1.56 a1=0.40 a2=0.10 pACD=5.77 sf=2.02 A=119.3 A=119.7 49 [4] The website is intended to provide information that might be of interest to users. Rayner Superflex 620 H A=118.0 a0=1.20 a1=0.40 a2=0.10 pACD=5.39 sf=1.64 A=118.8 A=119.0 144 [81],[88] Although not as intense as observed with the earlier 3-piece designs, pseudophakic dysphotopsia occurred in a few patients with the single-piece acrylic lens. [325]: data by Dr. Julio Fernandez Mendy, Buenos Aires, Argentina [3]: based on data by J.L.Parisi MD, Clemson SC, USA and Harvey K.Minatoya MD, Honolulu, HI, USA {148]: data by Dr.H.Schneider, Wismar, Germany [343]: data by Julio Fernandez Mendy MD, Buenos Aires, Argentina (**): results based on predominantly myopic patients (mean axial length: 24.48 +/- 1.87 mm) [77]: data by Dr.Baha Toygar, Istanbul, Turkey Constants are given without any legal responsibility ! [206]: data by Dr.J.L.Rodriguez Prats, Alicante, Spain H.Mller-Bergh MD(Itzehoe, Germany), Biotech Vision Eyecryl Plus ASHFY600 A=118.5 a0=1.20 a1=0.40 a2=0.10 pACD=5.43 sf=1.63 A=118.6 A=118.9 49 [369] [170]: data by Dr.A.Parasta, Mnchen, Germany [78]: data by Prof.Dr.Th.Neuhann, Mnchen, Germany [118]: data by Dr.H.Siggel, Brandenburg, Germany AMO ReZoom NXG1 A=118.4 a0=0.92 a1=0.40 a2=0.10 pACD=5.20 sf=1.40 A=118.3 A=118.5 113 [63],[131] 2013 Dec;39(12):1886-92. doi: 10.1016/j.jcrs.2013.06.021. [208]: data by Dr.H.Domack, Schweinfurt, Germany [242]: data by Noel Alpins MD, East Melbourne, Australia Nanavaty, M., et al. [331]: data by David Climenhaga MD, Edmonton, Alberta, Canada [216]: data by Dr.S.Bttmann, Ladenburg, Germany SIFI Mini Well A=118.6 a0=1.33 a1=0.40 a2=0.10 pACD=5.52 sf=1.73 A=118.8 A=119.1 49 [360] [90]: data by Dr.R.Wiedemann, Leipzig, Germany Hoya iMics Y-60H A=118.0 a0=1.13 a1=0.40 a2=0.10 pACD=5.32 sf=1.56 A=118.6 A=118.9 113 [221],[18] [52]: data by PD Dr.W.Sekundo, Marburg, Germany If the item is subject to FDA regulation, seller must verify your status as an authorized purchaser of this item before shipping of the item. Kaschube, Linares, Winkgen, Ldenscheid, Germany [56]: data by Dr.M.Meyer, Leer, Germany ZEISS CT ASPHINA 509M (Acri.Smart 36A) A=118.0 a0=0.68 a1=0.40 a2=0.10 pACD=4.90 sf=1.12 A=117.9 A=118.1 92 [111],[209] Wavefront aberrations, depth of focus, and contrast sensitivity with aspheric and spherical intraocular lenses: Fellow-eyestudy. [17]: data by J.Brndle, MD, Fssen, Germany [296]: data by Dr. A. Kerenyi, Budapest, Hungary Staar AQ 2003V A=118.5 a0=1.53 a1=0.40 a2=0.10 pACD=5.73 sf=1.96 A=119.2 A=119.6 65 [54] [84]: data by Dr.W.Bachmann,Aschaffenburg, Germany [120]: data by Dr.L.Tschernjakov, Berlin, Germany Polytech Polylens A60 A=118.0 a0=0.85 a1=0.40 a2=0.10 pACD=5.05 sf=1.31 A=118.2 A=118.6 57 [35] [119]: data by Prof.Dr.R.Welt, Ludwigshafen, Germany Fifty-four percent of the surgeons say they use the Alcon IQ Aspheric IOL for most of their cases, while 31 percent prefer the J&J Vision Tecnis one-piece lens. Proprietary Precision Edge Design3,4 Proprietary edge curvature designed to help reduce PCO and edge glare.3,4 Superior Axial Stability5,6 Fibronectin helps bind the material to the capsule, anchoring the lens in place to help reduce PCO and improve stability.4-6 Optical Design with Proven Performance3,4,7,8 Minimum quantity for "Alcon SA60AT AcrySof Single-Piece Acrylic Foldable IOL (x)" is 1. [249]: data by Dr.V.I.Apostolov, Amsterdam, The Netherlands [174]: data by Dr.S.Kretschmar, Bautzen, Germany In general, the typical SRK/T A-constant used for an IOL would be what you would use for the Hill-RBF calculator. Last Revision: Oct 31, 2016 WH, (*): A-const taken from: Mohr A, Hengerer F, Eckardt C: Retropupillare Fixation der Irisklauenlinse bei Aphakie. [234]: data by Dr.S.Day, Spokane, WA, USA Medicontur Bi-Flex 677 (hydrophil acryl) A=118.0 a0= 0.79 a1=0.40 a2=0.10 pACD=4.98 sf=1.19 A=118.0 A=118.0 103 [295],[63] Ralf and Matthias Gerl, Ahaus, Germany The Clareon PanOptix IOL is an advanced trifocal IOL equipped with ENLIGHTEN Optical Technologya proprietary design that optimizes intermediate vision without compromising exceptional near and distance vision.4,5 Hear what surgeons are saying about the CLAREON PanOptix IOL. Constants for IOLs characterized by '(Japan)'are based on results for Japanese eyes, which tend to be somewhat longer than Caucasian eyes. [224]: data by Dr.F.Bauer, Rosenheim, Germany [105]: data by Wavelight AG, Berlin, Germany [397]: data by Prof. Dr. Schnherr, Linz, Austria Eyeol LW5752R A=118.0 a0=1.27 a1=0.40 a2=0.10 pACD=5.46 sf=1.71 A=118.9 A=119.2 61 [343] IT TAKES SEEING THINGS DIFFERENTLY TO GO BEYOND. eyeonics AT-50SE crystalens A=119.0 a0= 0.318 a1=0.139 a2=0.182 pACD=5.62 sf=1.85 A=119.1 A=119.4 224 [115] [311]: data by Dr.T.Kohm, Karlsruhe, Germany [112]: data by P.Parden, MD, Coeur d' Alene, ID, USA A private practice in Marshalltown, Iowa, USA. Staar KS-3 A=119.0 a0=1.51 a1=0.40 a2=0.10 pACD=5.67 sf=1.91 A=119.1 A=119.8 63 [56] [242]: data by Noel Alpins MD, East Melbourne, Australia [261]: data by Dr. E.Mertens, Eersel, The Netherlands [304]: data by Dr.H.Kaymak, Dr.D.Breyer, Dsseldorf, Germany Moss Vision Optiflex MO/F-022 A=118.5 a0=1.37 a1=0.40 a2=0.10 pACD=5.61 sf=1.85 A=119.1 A=119.5 49 [369] MBI PreciSAL 302A/302AC A=118.7 a0=1.32 a1=0.40 a2=0.10 pACD=5.51 sf=1.75 A=118.9 A=119.2 190 [304],[332] [36]: data by J.Schrecker, MD, Glauchau, Germany [397]: data by Prof. Dr. Schnherr, Linz, Austria Moss Vision Optiflex MO/FNY-D003 A=118.0 a0=0.81 a1=0.40 a2=0.10 pACD=4.98 sf=1.19 A=117.9 A=118.1 49 [369] Aaren Scientific EC-3 PAL A=117.7 a0=1.10 a1=0.40 a2=0.10 pACD=5.28 sf=1.46 A=118.4 A=118.4 47 [365] [237]: data by Dr.Matteo Piovella, Monza, Italy [300]: data by Prof. Dr. Mike Holzer, Heidelberg, Germany [169]: data by Dr.Angel Lopez Castro, Madrid, Spain Bausch&Lomb Akreos FIT A=118.0 a0=0.78 a1=0.40 a2=0.10 pACD=5.02 sf=1.26 A=118.1 A=118.3 71 [24] Oculentis L-313 A=118.0 a0= 0.82 a1=0.40 a2=0.10 pACD=5.01 sf=1.26 A=118.1 A=118.4 23 [170] Alcon ReSTOR SV25T0 (India) A=119.1 a0=1.63 a1=0.40 a2=0.10 pACD=5.84 sf=2.05 A=119.3 A=119.6 16 [314] [80]: data by Dr. Kazuya Yamagishi, Japan Pedrell Pedrola, Barcelona, Spain [287]: data by Dr. Alexander Tunas, Hamburg, Germany Constant alcon sa60at forge a about accenture company Alcon Activefocus Restor 2.5 Multifocal Intraocular Lens. [15]: data by J.Chvojkova, MD, Prague, Czech Republic [326]: data by Dr. Paul O'Brian, Dublin, Ireland [133]: data by Keith Kellum, MD, Houma, LA, USA [72]: data by Dr.W.Htz, Bad Hersfeld, Germany [48]: data by Dr.A.Riel, Kiel, Germany [222]: data by Dr.H.Lgel, Sulzbach, Germany [393]: data by Dres Becker, Cordero, Maruniak. XP-55 A=118.0 a0=0.272 a1=0.245 a2=0.154 pACD=5.25 sf=1.48 A=118.5 A=118.8 259 [2],[18] The manufacturer's published A-constant was almost identical to that obtained in review (118.4 versus 118.38 for the SA30AL and 118.35 for the SA60AT). [40]: data by Dr.Jeffrey Sher, Hamilton, Ontario, Canada [378]: data by Dr. PARK Young Soon, Seoul, South Korea Graefes Arch Clin Exp Ophthalmol. For the Clareon Aspheric Toric IOLs, rotation can reduce astigmatic correction; if necessary lens repositioning should occur as early as possible prior to lens encapsulation. Ophtec PC 550 MonomaX A=118.0 a0=1.22 a1=0.40 a2=0.10 pACD=5.38 sf=1.63 A=118.7 A=119.0 103 [268],[274] A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses. Ciba memory lens CV232 A=119.0 a0=1.40 a1=0.40 a2=0.10 pACD=5.59 sf=1.82 A=119.0 A=119.5 61 [8] [381]: data by Dr. KIM Joung Mok, Seoul, South Korea The AcrySof IOL (model SA60AT) is an ultraviolet-absorbing acrylic foldable single-piece lens. [282]: data by Dr. Hendrik Hasche, Rostock, Germany [54]: data by Dr.A.Gross, Burghausen, Germany [288]: data by Aurolab, India ZEISS AT LISA 801 (Acri.LISA 376D) A=117.7 a0=0.82 a1=0.40 a2=0.10 pACD=5.06 sf=1.26 A=118.1 A=118.0 48 [231] WEFISinnovid WEFINO 100 A=118.7 a0= 1.39 a1=0.40; a2=0.10 pACD=5.56 sf=1.81 A=119.0 A=119.4 50 [84],[144] [309]: data by Dr.F.DeWilde, Sint Martens Latem, Belgium [381]: data by Dr. KIM Joung Mok, Seoul, South Korea [207]: data by Prof.Dr.N.Krber, Germany [212]: data by Dr.A.Ilkhani, Singen, Germany [340]: data by Dr. Hanemoto, Mito, Japan [3]: based on data by J.L.Parisi MD, Clemson SC, USA and Harvey K.Minatoya MD, Honolulu, HI, USA [102]: data by Fritz Ruck GmbH, Eschweiler, Germany [255]: data by Dr..Kavalcioglu, Istanbul, Turkey Eyeol Hyflex A=118.8 a0=1.54 a1=0.40 a2=0.10 pACD=5.69 sf=1.93 A=119.2 A=119.5 49 [325] [119]: data by Prof.Dr.R.Welt, Ludwigshafen, Germany [91]: data by Dr.S.Kohnen, Aachen, Germany [88]: data by Dr.F.Hhn, Ludwigshafen, Germany [94]: data by Polytech GmbH, Germany [214]: data by Dr.R.Beck, Rostock, Germany AMO Tecnis Z9002 A=118.7 a0= -1.201 a1=0.102 a2=0.246 pACD=5.46 sf=1.67 A=118.8 A=119.0 1275 [109],[139],[140],[19],[103],[104],[72],[98],[232],[234],[239] [111]: data by Dr.A.Schweiker, Pforzheim, Germany BETADINE is a registered trademark of The Purdue Frederick Company. [60]: data by V.Centurion, MD, Brazil i-Medical 6011C (HP60-PUV) A=118.8 a0=1.45 a1=0.40 a2=0.10 pACD=5.63 sf=1.85 A=119.1 A=119.4 51 [75] Setting: A-constant The constant is a theoretical value that relates the lens power to AL and keratometry, it is not expressed in units and is specific to the design of the IOL and its intended location and orientation within the eye. [344]: data by Randy Ennen MD, Fort Smith, AR, USA Xcelens IDEA (HEMA26%) A=119.0 a0=1.78 a1=0.40 a2=0.10 pACD=5.96 sf=2.19 A=119.6 A=120.1 55 [9] Curamed PL 600 A=118.8 a0=0.209 a1=0.124 a2=0.182 pACD=5.46 sf=1.68 A=118.8 A=119.0 180 [218],[219] [128]: data by Dr.P.Schels, Passau, Germany After surgery, physicians should provide an implant card to patients regarding the IOL implanted. [247]: data by Dr.Franc Salamun, Nova Gorica, Slovenia [129]: data by J.Chappell MD, Chicago, IL, USA [56]: data by Dr.M.Meyer, Leer, Germany [373]: data by Dr. Edith Krehn, Bayreuth, Germany [384]: data by Prof. JOO Choun-Ki, Seaoul, South Korea [47]: data by Dr.Y.Walpuski, Kiel, Germany Nejima R, Miyata K, Honbou M, Tokunaga T, Tanabe T, Sato M, Oshika T. Br J Ophthalmol. Below are lens constants for popular IOLs to be used with the Hill-RBF calculator. Zeiss CT LUCIA 601P/PY A=119.1 a0=1.49 a1=0.40 a2=0.10 pACD=5.70 sf=1.94 A=119.2 A=119.6 77 [223],[316],[375] Unauthorized use of these marks is strictly prohibited. [231]: data by Dr.A.Bach, Schwerin, Germany (For details how to create your own tentative constants, Augsburg,Herzberg, Germany document.write(part3 + '<\/a>'); [285]: data by Dr. Miguel Angel Perez, Gran Canaria, Spain One-year multicenter evaluation of a new hydrophobic acrylic intraocular lens with hydroxyethyl methacrylate in an automated preloaded delivery system. If optimized lens constants are not available, these should be considered as only a starting point. Dr.Schmidt MC6125AS A=118.4 a0=0.885 a1=0.312 a2=0.125 pACD=5.36 sf=1.60 A=118.7 A=119.1 204 [70],[122] [278]: data by Jason Jacobs, MD, Denver, CO, USA Ecuador [346]: data by Dr. Rudolf Sieben, Aachen, Germany ALCON SA60AT Intraocular Lens 25.0D, Length 13.0mm, Optic 6.00mm SRK/T Optical A-Constant : 118.7 SRK/T Ultrasound A-Constant :118.3 All items listed are on inventory. Curamed HD60CZ-YA A=118.4 a0=1.30 a1=0.40 a2=0.10 pACD=5.50 sf=1.72 A=118.9 A=119.2 127 [391] [290]: data by Dr. J.M. [312]: data by Dr.Frhlich, Freiburg i.Br [9]: based on data by M.Kchle, MD, Erlangen, Germany [361]: data by Dr. Thomas Hamacher, Starnberg, Germany Fritz Ruck HA-4-Q A=118.1 a0=1.14 a1=0.40 a2=0.10 pACD=5.29 sf=1.52 A=118.6 A=118.9 88 [102] Overall, the IOLs were easy to implant with no haptic or optic damage using a forceps or the Monarch injector. . [350]: data by Dres. [97]: data by Asim Piracha, MD, West Mifflin, PA, USA Polytech Polylens A61 (+) A=118.2 a0=0.86 a1=0.40 a2=0.10 pACD=5.06 sf=1.29 A=118.2 A=118.4 79 [13],[29] A-constant validation. Bausch&Lomb L 122UV A=115.8 a0= -1.10 a1=0.40 a2=0.10 pACD=3.17 sf= -0.60 A=115.1 A=115.3 22 [299] [66]: data by Dr.S.Schler, Minden, Germany [9]: based on data by M.Kchle, MD, Erlangen, Germany [63]: data by Dr.C.Binder, Schramberg, Germany Krmer, Domeier und Pache, Lbeck, Germany [335]: data by Dr. Ralf Gerl, Ahaus, Germany [30]: data by Dr.G.Hring, Rendsburg, Germany [345]: data by Dres.Selbach, Kremmer et Anastassiou, Gelsenkirchen, Germany PLAY VIDEO [163]: data by Dr.H.Hofmann, Schaffhausen, Switzerland [277]: data by Dr.M.Winter, Bremen, Germany The AcrySof IQ lens is designed to enhance contrast sensitivity, reduce spherical aberration, and improve functional vision. If optimized lens constants are not available, these should be considered as only a starting . Eyekon SC25-Fold A=118.0 a0=0.92 a1=0.40 a2=0.10 pACD=5.08 sf=1.31 A=118.2 A=118.5 213 [341] [338]: data by Dr. Ruth Lapid-Gortzak, Driebergen, The Netherlands [38]: data by Dr.Michaela Mees, Sulzbach, Germany [62]: data by Dr.K.Binder, Schramberg, Germany AMO Verisyse 50 aph.retropup. [343]: data by Julio Fernandez Mendy MD, Buenos Aires, Argentina [49]: data by Dr.D.Holland, Kiel, Germany Keith A.Gross MD, New Zealand, [11]: data by Dr.B.Hrster and Dr.Thamaz, Erkelenz, Germany MD-TECH I-Stream ISP A=118.0 a0=1.46 a1=0.40 a2=0.10 pACD=5.74 sf=1.97 A=119.2 A=119.6 14 [284] [29]: data by Dr.D.Johann, Koblenz, Germany [88]: data by Dr.F.Hhn, Ludwigshafen, Germany [165]: data by Dr.R.Friedrich, Meiningen, Germany [34]: data by D.Rotmann, MD, Nordhorn, Germany [236]: data by Dr.H.v.Wyk, Johannesburg, South Africa [113]: data by R.Arleo, MD, Ithaca, Ithaca, NY, USA document.write(''); [98]: data by A.Rivett, Adelaide, Australia ARGONOPTICS EUROMAXX A=118.0 a0=0.87 a1=0.40 a2=0.10 pACD=5.09 sf=1.33 A=118.2 A=118.5 105 [43] [222]: data by Dr.H.Lgel, Sulzbach, Germany [159]: data by John Merriam, MD, columbia.edu, USA [6]: based on data by different surgeons from Eye Clinic Kln-Merheim, Germany [34]: data by D.Rotmann, MD, Nordhorn, Germany Alcon ReSTOR SA60D3 A=118.1 a0= -0.123 a1=0.099 a2=0.189 pACD=5.23 sf=1.46 A=118.5 A=118.7 339 [57],[58],[59],[60],[61],[85] [86]: data by Dr.E.Becker, Oranienburg, Germany Oculentis LS-502-1 A=118.0 a0= -1.014 a1=0.153 a2=0.227 pACD=5.36 sf=1.59 A=118.7 A=119.0 230 [160],[161] [131]: data by Dr.M.Rau, Furth i.W., Germany C.Grenauer-Kloevekorn, Halle, Germany Morcher TYPE 92S A=119.7 a0=1.40 a1=0.40 a2=0.10 pACD=5.60 sf=1.84 A=119.1 A=119.6 71 ]362] Effectiveness and Safety of the Clareon. [75]: data by Dr.U.Heuer, Hamburg, Germany [168]: data by Dr.C.Wirbelauer, Berlin, Germany Fibronectin helps bind the material to the capsule, anchoring the lens in place to help reduce PCO and improve stability. These lens constants are offered only as a recommendation for a starting . Len.s constants must be "personalized" to compensate for the diffierences in instrumentation, measurement technique, and [OL, power calculation methods. [13]: data by Dr.U.Giers, Detmold, Germany Kaschube, Linares, Winkgen, Ldenscheid, Germany Model Characteristics Chart Model Optic Type Haptic Angle Anterior Asymmetric Biconvex DESCRIPTION The AcrySof IQ UV and blue light filtering acrylic foldable single-piece posterior chamber intraocular lens (IOL) is an optical implant for the replacement of the human crystalline lens in the visual correction of aphakia in adult patients For relations between IOL constants for optical and acoustical biometry click here. The patients of group 1 were given an aspherical IOL Z9001 (AMO, Santa Ana, CA, USA) replacement, and group 2 was implanted a monofocal IOL SA60AT (Alcon, Fort Worth, TX, USA) and group 3 the . Posterior capsule opacification and neodymium:YAG rates with 2 single-piece hydrophobic acrylic intraocular lenses: three-year results. In verbal descriptions, IOL optic centration was assessed to be within 0.4 mm of perfect in 75 (95%) of 79 cases. J Cataract Refract Surg. [376]: data by Mr. Mark Cahill, Dublin, Ireland [112]: data by P.Parden, MD, Coeur d' Alene, ID, USA [16]: data by J.W.Klett, MD, Dortmund Comodo uses strategically than statements of remote access to optimal intersections of.

Gatwick Shuttle Bus Timetable, Articles A

alcon sa60at a constant

alcon sa60at a constantAdd a Comment